High-sensitive cardiac troponin hs-TnT levels in sudden deaths related to atherosclerotic coronary artery disease.

TitreHigh-sensitive cardiac troponin hs-TnT levels in sudden deaths related to atherosclerotic coronary artery disease.
Publication TypeJournal Article
Year of Publication2018
AuthorsBeausire, T, Faouzi, M, Palmiere, C, Fracasso, T, Michaud, K
JournalForensic science international
Volume289
Pagination238-243
Date Published06/2018
DOI10.1016/j.forsciint.2018.05.051
ISSN1872-6283
Mots-clésHigh-sensitive cardiac troponin hs-TnT, Myocardial Ischemia, Sudden death
Abstract

INTRODUCTION: Ischemic heart disease (IHD) related to atherosclerotic coronary artery disease (CAD) is one of the most prevalent causes of death in Europe. Postmortem evaluation of IHD remains a challenge because of possible non-specific autopsy finding in some autopsy cases, especially in early myocardial ischemia. High-sensitive cardiac troponin T (hs-TnT) is used today in clinical practice as the "gold standard" to diagnose the myocardial ischemia, and might also be applied as an ancillary tool for post-mortem evaluation.

PURPOSE: The goal of this study is to evaluate the diagnostic value of post-mortem serum hs-TnT assay in cases of sudden death related to IHD. We will also investigate the influence of cardiopulmonary resuscitation (CPR) attempts on post-mortem hs-TnT levels.

METHODS: The hs-TnT values in serum were retrospectively analysed in 85 autopsy data. 52 cases with clinical history and morphological results suggesting cardiac ischemia were included in the study group (mean age 53.5; age range 34-75) and 33 cases in the control group (mean age 40.4; age range 15-69). The group's statistical comparison was performed using logistic regression model.

RESULTS: Our study showed a significant non-linear association between hs-TnT serum values and post-mortem diagnosis of sudden deaths related to IHD (p-value 0.005). The shape of the relationship is showing that the probability of death due to IHD increases quickly with a light level of hs-TnT (maximum around 90ng/L) then decreases slightly while remaining at high in values. No significant difference in the hs-TnT serum values was found between the CPR and the non-CPR cases (p-value 0.304).

CONCLUSION: The measurement of hs-TnT serum values might be considered as an ancillary tool for the evaluation of death related to IHD, while taking necessary precautions in the interpretation of the results.

Alternate URL

http://www.ncbi.nlm.nih.gov/pubmed/29908517?dopt=Abstract

WOS ID (UT)

000438589000035

Alternate JournalForensic Sci. Int.
Citation Key / SERVAL ID8941
Peer reviewRefereed
PubMed ID29908517

                         

IUMSP | www.iumsp.ch
Institut universitaire de médecine sociale et préventive
Route de la Corniche 10, 1010 Lausanne - Switzerland
+41 21 314 72 72 | dess.info@unisante.ch

Go to top